2. |
Disconnect evaporator temperature
sensor. |
3. |
Using the multi-tester, Measure resistance
between terminal "1" and "2" of evaporator temperature
sensor.

[Specification]
Evaporator core
temperature [°C(°F)]
|
Resistance
[kΩ]
|
-10
(14)
|
43.35
|
-5
(23)
|
34.48
|
0
(32)
|
27.62
|
5
(41)
|
22.27
|
10
(50)
|
18.07
|
15
(59)
|
14.75
|
20
(68)
|
12.11
|
25
(77)
|
10.00
|
30
(86)
|
8.30
|
35
(95)
|
6.93
|
40
(104)
|
5.81
|
45
(113)
|
4.9
|
50
(122)
|
4.15
|
|
4. |
If the measured resistance is not
specification, substitute with a known-good evaporator temperature
sensor and check for proper
operation. |
5. |
If the problem is corrected, replace the
evaporator temperature sensor. |
1. |
Disconnect the negative (-) battery
terminal. |
2. |
Remove the extenser cover (A).

|
3. |
Disconnect the evaporator sensor connector
(A). |
4. |
Remove the evaporator temperature sensor (B),
by pulling it after rorating 90° in a counter clock wise
direction.

Take care that evaporator core pins are
not bent. | |
5. |
Installation is the reverse order of
removal. | |