VERACRUZ(EN)
>2008 > G 3.8 DOHC > Emission Control
System > Crankcase Emission Control
System > Positive Crankcase Ventilation (PCV) Valve>Repair
procedures
REMOVAL
1.
Remove the valve pad (A) and disconnect the
vacuum hose (B).
2.
Remove the PCV
vavle.
INSPECTION
1.
Remove the PCV
valve.
2.
Insert a thin stick(A) into the PCV valve(B)
from the threaded side to check that the plunger
moves.
3.
If the plunger does not move, the PCV valve
is clogged. Clean it or replace.
INSTALLATION
Install the PCV valve
and tighten to the specified torque.