VERACRUZ(EN) >2008 > G 3.8 DOHC > Body Electrical System > AC Inverter System>Specifications  
SPECIFICATIONS
A/C INVERTER UNIT
Items
Specifications
Input voltage range
DC 9.0 ~ 16.0V
Operating voltage range
DC 12.7 ~ 15.0V
A/C output voltage range
AC 103.5 ~ 126.5Vrma
A/C output frequency
54 ~ 66Hz
A/C output wave form
Modified sine wave
Cooling system
Natural cooling
Maximum output power
150W MIN.
75W MIN.
(With resistance load)
Operating temperature range
-30 ~ +75°C (-22 ~ 167°F)
Storage temperature range
-40 ~ +85°C (-40 ~ 185°F)
Protective function
Input high voltage protection
-
When input voltage is between 15V and 17V, the DC/AC inverter stops AC output.
-
And when input voltage becomes less than 15V, the DC/AC inverter restart.
-
When input voltage exceeds 17V furthar, the DC/AC inverter opens an own relay and shotdown itself.
Input low voltage protection
-
When input voltage is less then 10.8V, the DC/AC inverter stops its AC output.
-
And when input voltage exceeds 12.7V, the DC/AC inverter rastart.
Output high voltage protection
-
When output wave height exceeds 170V, the DC/AC inverter stops its AC output
-
And when it becomes less than 170V, the DC/AC inverter rastart
Output over current protection
-
When the load exceeding 150W is connected to the DC/AC inverter it will be OCL (Over current limit) -mode to defend over current.
-
If OCL mode continues during about 2sec., the DC/AC inverter stops its output.
-
After it passes over 40sec from the DC/AC inverter stops, the inverter restarts its output.
Output low voltage protection
-
When the output voltage is below the setup value, the DC/AC inverter stops its output.
-
When the output low voltage protection is worked on, the DC/AC inverter shuts down.
-
To restart DC/AC inverter, 'IG-off-ON' is necessary.
Over heat protection
-
When the temperature inside or DC/AC inverter rises and a regular level is exceeded, the DC/AC inverter stops its output.
-
When the over heat protection is worked on, the DC/AC inverter shuts down.
-
To restart DC/AC inverter, 'IG-off-ON' is necessary
Outlet LED
-
When the DC/AC inverter is providing AC power, outlet LED is lighting.
-
When input voltage is between 11.0 and 10.8, outlet LED is blinking (The blink frequency is about 2Hz.)
-
When input voltage is under 10.8V, outlet LED is stops operating.
-
When the DC/AC inverter is not providing AC power, outlet LED is unlighting.

A/C INVERTER OUTLET
Items
Specifications
Outlet rating
125VrmsAC and 3ArmsAC
Insulation resistance
10Mohm, which measured at 500V
Contact resistance
Less than or equal to 50mohm.
Color
Black
Operating temperature
-30°C ~ 75°C (-22 ~ 167°F)
Preservation temperature
-40°C ~ 85°C (-40 ~ 185°F)
Material
ABS
LED color
Red