Items
|
Specifications
|
Input voltage range
|
DC 9.0 ~ 16.0V
|
Operating voltage range
|
DC 12.7 ~ 15.0V
|
A/C output voltage range
|
AC 103.5 ~ 126.5Vrma
|
A/C output frequency
|
54 ~ 66Hz
|
A/C output wave form
|
Modified sine wave
|
Cooling system
|
Natural cooling
|
Maximum output power
|
150W MIN. 75W
MIN. (With resistance
load)
|
Operating temperature range
|
-30 ~ +75°C (-22 ~
167°F)
|
Storage temperature range
|
-40 ~ +85°C (-40 ~
185°F)
|
Protective function
|
Input high voltage protection
|
-
|
When input voltage is between 15V and
17V, the DC/AC inverter stops AC
output. |
-
|
And when input voltage becomes less
than 15V, the DC/AC inverter
restart. |
-
|
When input voltage exceeds 17V
furthar, the DC/AC inverter opens an own relay and shotdown
itself. | |
Input low voltage protection
|
-
|
When input voltage is less then 10.8V,
the DC/AC inverter stops its AC
output. |
-
|
And when input voltage exceeds 12.7V,
the DC/AC inverter
rastart. | |
Output high voltage protection
|
-
|
When output wave height exceeds 170V,
the DC/AC inverter stops its AC
output |
-
|
And when it becomes less than 170V,
the DC/AC inverter
rastart | |
Output over current protection
|
-
|
When the load exceeding 150W is
connected to the DC/AC inverter it will be OCL (Over current
limit) -mode to defend over
current. |
-
|
If OCL mode continues during about
2sec., the DC/AC inverter stops its
output. |
-
|
After it passes over 40sec from the
DC/AC inverter stops, the inverter restarts its
output. | |
Output low voltage protection
|
-
|
When the output voltage is below the
setup value, the DC/AC inverter stops its
output. |
-
|
When the output low voltage protection
is worked on, the DC/AC inverter shuts
down. |
-
|
To restart DC/AC inverter, 'IG-off-ON'
is necessary. | |
Over heat protection
|
-
|
When the temperature inside or DC/AC
inverter rises and a regular level is exceeded, the DC/AC
inverter stops its output. |
-
|
When the over heat protection is
worked on, the DC/AC inverter shuts
down. |
-
|
To restart DC/AC inverter, 'IG-off-ON'
is necessary | |
Outlet LED
|
-
|
When the DC/AC inverter is providing
AC power, outlet LED is
lighting. |
-
|
When input voltage is between 11.0 and
10.8, outlet LED is blinking (The blink frequency is about
2Hz.) |
-
|
When input voltage is under 10.8V,
outlet LED is stops
operating. |
-
|
When the DC/AC inverter is not
providing AC power, outlet LED is
unlighting. | |