Immobilizer Related
Faults
|
Fault types
|
Diagnostic
codes
|
PCM(ECM) fault
|
1. |
Non-Immobilizer-EMS connected to an
Immobilizer | |
P1610
|
Transponder key fault
|
1. |
Transponder not in password
mode |
2. |
Transponder transport data has been
changed. | |
P1674 (Transponder status
error)
|
Transponder key fault
|
1. |
Transponder programming
error | |
P1675 (Transponder
programming error)
|
SMARTRA fault
|
1. |
Invalid message from SMARTRA to
PCM(ECM) | |
P1676 (SMARTRA message
error)
|
SMARTRA fault
|
1. |
Virgin SMARTRA at learnt
EMS |
2. |
Neutral SMARTRA at learnt
EMS |
3. |
Incorect the Authentication of EMS and
SMARTRA |
|
P169A(SMARTRA Authentication fail)
|
SMARTRA fault
|
1. |
No response from
SMARTRA |
3. |
Communication line error (Open/Short
etc.) |
4. |
Invalid message from SMARTRA to
PCM(ECM) | |
P1690 (SMARTRA no
response)
|
Antenna coil fault
|
1. |
Antenna coil open/short
circuit | |
P1691 (Antenna coil
error)
|
Immobilizer indicator lamp fault
|
1. |
Immobilizer indicator lamp error
(Cluster) | |
P1692 (Immobilizer lamp
error)
|
Transponder key fault
|
1. |
Corrupted data from
transponder |
2. |
More than one transponder in the
magnetic field (Antenna coil) |
3. |
No transponder (Key without
transponder) in the magnetic field (Antenna
coil) | |
P1693 (Transponder no
response error/invalid response)
|
PCM(ECM) fault
|
1. |
Request from PCM(ECM) is
invalid
(Protocol layer violation- Invalid
request, check sum error
etc.) | |
P1694 (PCM(ECM) message
error)
|
PCM(ECM) internal permanent memory (EEPROM)
fault
|
1. |
PCM(ECM) internal permanent memory
(EEPROM) fault |
2. |
Invalid write operation to permanent
memory (EEPROM) | |
P1695 (PCM(ECM) memory
error)
|
Invalid key fault
|
1. |
Virgin transponder at PCM(ECM) status
"Learnt"Learnt (Invalid) Transponder at PCM(ECM) status
"Learnt"(Authentication
fail) | |
P1696 (Authentication
fail)
|
Hi-Scan fault
|
|
P1697
|
Locked by timer
|
1. |
Exceeding the maximum limit of Twice
IGN ON (⊇ 32 times) | |
P1699 (Twice IG ON over
trial)
|