VERACRUZ(EN) >2007 > G 3.8 DOHC > Body Electrical System > Lighting System > Hazard Lamp Switch>Repair procedures  
INSPECTION
HAZARD LAMP SWITCH
1.
Disconnect the negative (-) battery terminal.
2.
Remove the air vent panel (A).
(Refer to the Body group - Crash pad)

3.
Disconnect the connectors.
4.
Operate the switch and check for continuity between terminals with an ohmmeter.